Parts and components for devices manufactured by the TATAREK company from the section of consumer automation systems as well as additional equipment cooperating with the controllers to complete the installation of heating systems and increase the comfort of their use.
Temperature sensor of the KTY series with the STB (0…+100°C) protection is intended for the RT-01B and RT-02B controllers to measure water temperature in the boiler.
Temperature sensor of the boiler water (0…+100°C) is intended for the RT-01 ANIA and RT-02 ANETA controllers to measure water temperature in the boiler.
The RT-01 ANIA and RT-02 ANETA controllers are no longer manufactured.
Temperature sensor of the boiler water with STB (0…+100°C) is intended for the RT-04B ADAŚ and RT-04C controllers to measure water temperature in the boiler.
Sensor for measuring temperature of flue gas (0 ... 1200 ° C) in stoves and stove-fitting furnaces for the controllers RT-08OM / OMG, RT-08OS / OSG RT-08SAC. When used in furnaces where the sleeve of the sensor is exposed to direct contact with flames an extra ceramic cover is required to be applied !!!
Due to the specific construction of the sensor cable in case you need an extension cord it is necessary to use a dedicated extension of the sensor of the same parameters!
Sensor for measuring temperature of flue gas (0 ... 1200 ° C) in stoves and stove-fitting furnaces for the controllers RT-08OM / OMG, RT-08OS / OSG, RT-08SAC.
This thermocouple is constructed bent, so it can be used in places where the standard simple solution is not fit. When used in furnaces where the sleeve of the sensor is exposed to direct contact with flames an extra ceramic cover is required to be applied !!! Due to the specific construction of the sensor cable in case you need an extension cord it is necessary to use a dedicated extension of the sensor of the same parameters!
CERAMIC COVER FOR THERMOCOUPLE 12 Ceramic cover for the flue gas sensor dedicated to type K thermocouple sensors. Protects the sensor measuring post against direct exposure to flames. Parameters:
Length: 120 mm Thread: M8x1 Outer diameter of cover: Ø6 Inside diameter of cover: Ø4
TEMPERATURE SENSOR OF STOVE WATER ((0…+100°C) for the controllers: RT-08G, RT-08P, RT-08K, RT-08OS
The essential temperature sensor of water in the stove water jacket for the controllers: RT-08G, RT-08P, RT-08K, RT-08OS with extra temperature protection of the cable.
TATAREK reed relay door sensor - the sensor is intended for use with the controllers RT-08 OM, the RT-08 OS, SAC RT-08 and RT-08 OS GRAFIK. It detects the firebox opening. By using this type of sensor the combustion process can be automatically suspended by the controller while the air damper is being fully opened. The closing of the door switches the controller to an automatic reading of the burning parameters, and then depending on the temperature distribution and the dynamics of their growth or decline – the restoration of a proper burning phase at the given moment occurs.
The air damper having a diameter of 100 mm, without the seal or with the seal of the control wing dedicated to supply air to the combustion chamber in stoves with water jacket, stove-fitting furnaces and air stoves.
The Ø 100 mm unsealed air damper is dedicated for controllers such as: RT-08G, RT-08P, ZRP1 It brings air into the combustion chamber in stoves with water jacket. The minimum gap around the air damper wing provides minimum airflow, allowing to balance the pressure difference and thus prevents this kind of inserts from damage in case of adverse weather conditions or when power failure occurs.
The Ø 100 mm sealed air damper is dedicated for controllers such as: RT-08OM, RT-08OS, RT-08SAC
The air damper having a diameter of 120 mm, without the seal or with the seal of the control wing dedicated to supply air to the combustion chamber in stoves with water jacket, stove-fitting furnaces and air stoves.
The Ø 120 mm unsealed air damper is dedicated for controllers such as: RT-08G, RT-08P, ZRP1 It brings air into the combustion chamber in stoves with water jacket. The minimum gap around the air damper wing provides minimum airflow, allowing to balance the pressure difference and thus prevents this kind of inserts from damage in case of adverse weather conditions or when power failure occurs.
The Ø 120 mm sealed air damper is dedicated for controllers such as: RT-08OM, RT-08OS, RT-08SAC
The air damper having a diameter of 150 mm, without the seal or with the seal of the control wing dedicated to supply air to the combustion chamber in stoves with water jacket, stove-fitting furnaces and air stoves.
The Ø 150 mm unsealed air damper is dedicated for controllers such as: RT-08G, RT-08P, ZRP1 It brings air into the combustion chamber in stoves with water jacket. The minimum gap around the air damper wing provides minimum airflow, allowing to balance the pressure difference and thus prevents this kind of inserts from damage in case of adverse weather conditions or when power failure occurs.
The Ø 150 mm sealed air damper is dedicated for controllers such as: RT-08OM, RT-08OS, RT-08SAC
DUO damper Ø 120 mm. Cold air damper with a diameter of 120 mm, symmetrically divided into two independently adjustable air ducts. It allows, in combination with a dedicated controller, for fully automatic regulation of the amount of air supplied to the furnace - separately for the primary and secondary air supply channels.
ONLY FOR USE WITH THE CONTROLLERS IN THE DUO VERSION !!! RT-08 G DUO; RT-08 G BUFFER DUO, RT-08 OM GRAFIK DUO DUO dampers may differ slightly in execution for specific manufacturers !!!
CONTROLLERS OFFERED ONLY BY MANUFACTURERS OF STOVE INSERTS AND FURNACES !!!
DUO damper Ø 150 mm. Cold air damper with a diameter of 150 mm, symmetrically divided into two independently adjustable air ducts. It allows, in combination with a dedicated controller, for fully automatic regulation of the amount of air supplied to the furnace - separately for the primary and secondary air supply channels.
ONLY FOR USE WITH THE CONTROLLERS IN THE DUO VERSION !!! RT-08 G DUO; RT-08 G BUFFER DUO, RT-08 OM GRAFIK DUO DUO dampers may differ slightly in execution for specific manufacturers !!!
CONTROLLERS OFFERED ONLY BY MANUFACTURERS OF STOVE INSERTS AND FURNACES !!!
Cover frame for controllers with graphic displays from the family RT-08: RT-08 G; RT-08 G BUFOR, RT-08 BUFOR SOLAR, RT-08 OS GRAFIK; RT-08 OM GRAFIK, RT-08 GX
Cover frame for controllers with graphic displays from the familyRT-08: RT-08 G; RT-08 G BUFOR, RT-08 BUFOR SOLAR, RT-08 OS GRAFIK; RT-08 OM GRAFIK, RT-08 GX
The GAZEX detector is designed for a continuous monitoring of carbon monoxide in areas at risk of emission of this gas. The control is based on a cyclical measurement of CO concentration in the ambient air. After exceeding a determined value of CO and a determined time of exposure the alarm signalling of the detector is switched on. The alarm is turned on at a concentration over 0.005% of CO after an exposure time of over 60 minutes or at a concentration of 0.01% after 10 min or at a concentration of 0.03% within 3 min. (in accordance with European standard EN 50291) The detector can work with stove controllers of the company TATAREK.
The mounting kit of the BELIMO TF230 servomotor is a kit for mounting the Belimo TF230 servomotor. The kit mounts it stable in a flat or side position, providing a full transfer of power of the servomotor to the chimney flap.For the mentioned kit it is necessary to buy a power transmission rod of a diameter of 6 mm and any length depending on the installation place of the servomotor. This servomotor has been selected after extensive tests and provides the appropriate force necessary for running the operation of the chimney flap at all times (even when the impurities gather). It has the return spring that gets the flap back to its original position if a power failure occurs, which is the location that guarantees complete safety of the system.
The BELIMO TF230 servomotor is used to drive the chimney flap and it's a device that combined with the controllers RT-08 SAC, RT-08 OS and RT-08 OS GRAFIK ensures a fully automatic operation of heat storage systems also in conjunction with the cooperating water base. This servomotor has been selected after extensive tests and provides the appropriate force necessary for running the operation of the chimney flap at all times (even when the impurities gather). It has the return spring that gets the flap back to its original position if a power failure occurs, which is the location that guarantees complete safety of the system.